Choosing PVC Strip Curtains for Pedestrian-Only Doorways
For pedestrian-only doorways, choose PVC strip curtains that people can push through comfortably, with enough overlap to reduce draughts. Strip width, thickness, material grade and mounting position all affect how easily the curtain moves and closes.
A heavy-duty curtain can make a staff entrance unnecessarily awkward, while a poorly fitted lightweight curtain can leave persistent gaps. The priority is comfortable passage, matched to the temperature, airflow and cleaning needs of your workplace.
Start with how people use the doorway, then choose the specification around them.
Key takeaways
- For many pedestrian openings under 3 m high, 200 mm wide, 2 mm thick strips are a useful starting point.
- Wider strips and greater overlap increase the material people must push aside, so heavier specifications need a clear reason.
- Clear PVC supports visibility, but it doesn’t replace separate pedestrian routes.
- Temperature grade, mounting position and finished drop matter alongside strip dimensions.
- Choose replaceable strips and accessible fixings to make cleaning and repairs easier.
Start with the people using the doorway

Understand everyday access needs
Consider how often staff pass through and what they carry. A person walking empty-handed has different access needs from someone carrying bulky cartons or wearing protective clothing.
The curtain should part without excessive effort and return after normal passage. If staff routinely hold strips aside or tie them back, the arrangement may be too restrictive for the work.
Also consider users with reduced mobility. Hanging strips create physical contact, so they aren’t suitable for every accessible route. An automatic door or another entrance arrangement may provide better access where pushing through flexible material presents a difficulty.
Keep the route genuinely pedestrian-only
A pedestrian-only opening should remain separate from forklift and vehicle movements. HSE’s guidance on separating pedestrians and vehicles identifies entirely separate routes as the most effective approach.
Clear strips help people see approaching colleagues, but scratches, reflections and dirt can reduce that view. Therefore, transparency supports an existing safe layout rather than replacing it.
Position storage and equipment away from both approaches. People need space to pause and see through the curtain before entering, particularly where two-way foot traffic meets at a narrow doorway.
Choose strip width, thickness and overlap together
These three choices affect both separation and walking resistance. Treat them as one specification rather than choosing each in isolation.
Start with pedestrian-friendly dimensions
For many pedestrian openings under 3 m high, 200 mm x 2 mm strips offer a practical starting point. Our strip width and thickness guide also covers 300 mm x 2 mm strips for pedestrian and light-industrial applications.
These are application recommendations, rather than universal rules. Doorway height, air movement and frequency of passage still affect the choice.
Thicker PVC carries more weight, while wider strips require people to displace a larger panel. Consequently, choosing the largest available format can make a small internal doorway harder to use without solving the actual draught problem.
Balance overlap against walking resistance
Overlap is the amount each strip covers its neighbour. Increasing it can improve coverage, but it also puts more material across the walking route.
For pedestrian access, avoid specifying dense coverage simply because it looks more substantial. The curtain must remain manageable throughout a shift, including for people carrying items.
Judge closure after someone walks through. A curtain that looks well covered at rest can still leave gaps if strips catch or remain folded aside.
Look for strips that hang evenly and return without snagging. Where strong air movement repeatedly blows them apart, the wider entrance arrangement may need attention.

Match the PVC grade to the working environment
Separate temperature grade from thickness
Strip dimensions don’t establish low-temperature flexibility. Standard and cold-store grades have different operating characteristics, so a thicker standard strip isn’t automatically the right choice for a chilled doorway.
Use the actual conditions on both sides of the opening to select the material. Cold, condensation and exposure to cleaning products can all affect the specification.
PVC strip curtains reduce air exchange, but air can still move between strips and beneath the curtain. They work best as part of a suitable temperature-control arrangement, rather than as a substitute for an insulated external door.
Keep ventilation and specialist requirements separate
Reducing an uncomfortable draught mustn’t remove the fresh air a workplace needs. HSE’s guidance on balancing ventilation and warmth addresses that distinction.
Likewise, a curtain isn’t a substitute for extraction where work produces hazardous dust or fumes. Airflow control needs to account for the process on either side.
For food-handling areas, select material suited to the cleaning regime and intended application. Clear PVC alone doesn’t establish suitability for food contact.
Anti-static requirements also need their own specification. A material intended to reduce nuisance static isn’t automatically suitable for an electrostatic discharge-protected area or a hazardous atmosphere.
Measure the opening and plan the mounting
Record more than one width and drop
Measure the clear opening at several heights, then measure the drop at several positions across it. Record everything in millimetres so differences are easy to identify.
A sloping floor, uneven lintel or projecting shutter guide can change the finished curtain dimensions. Therefore, keep the opening size, rail length and curtain coverage as separate measurements.
Measure the finished drop from the actual hanging position. Measuring only from the top of the doorway can produce strips that are too long or short once the rail and suspension plates are fitted.
Allow for the structure and existing doors
The mounting surface must support the rail and repeated pulling forces. Thin cladding or an insulated panel face may need a different fixing arrangement from sound masonry or structural steel.
Also allow for existing door leaves, closers, shutter guides and overhead equipment. Nothing should catch the strips during normal operation.
At floor level, avoid dragging strips and excessive gaps. Keep approaches unobstructed and pedestrian-only areas clearly marked, consistent with HSE’s workplace route guidance.
Our PVC strip curtain installation service provides made-to-measure arrangements around the opening and its access requirements.
Compare the installed cost and ongoing care
Compare equivalent curtain specifications
A meaningful quotation should describe the opening dimensions, strip size, material grade, overlap and mounting system. Otherwise, two prices may cover substantially different curtains.
Wider openings and greater overlap use more PVC. Specialist grades, support work and installation access also affect the total cost.
Include removal of an existing curtain or rail where required. A low initial price offers little benefit if the finished curtain leaves gaps or makes access awkward.
For an external entrance, budget separately for the security and weather barrier. Flexible PVC doesn’t provide intruder protection, so the existing shutter or lockable door still has its own job.
Make cleaning and replacement straightforward
Hook-on and bolt-on systems commonly allow individual strips to be replaced without changing the whole curtain. Choose hardware that suits the cleaning routine and allows safe maintenance access.
During routine inspections, look for splits, curling edges, missing overlap and loose suspension plates. Cloudy or heavily scratched material can also reduce visibility across the doorway.
Our guidance on cleaning PVC strip curtains safely covers gentle cleaning methods that protect serviceable material.
Cleaning won’t repair cracked strips or restore lost flexibility. Replace damaged sections before persistent gaps or snagging interfere with daily use, and keep replacement strips consistent with the original layout.
Frequently asked questions
Are 200 mm x 2 mm strips always right for pedestrian doors?
No. They’re a useful starting point for many pedestrian openings under 3 m high, but they don’t suit every installation. Opening height, temperature, air movement and passage frequency affect the final choice. A taller or more exposed doorway may need a different arrangement, while accessibility needs may favour another type of door.
Can PVC strip curtains remain behind an existing door?
Yes, where there is enough space for both systems to operate independently. The curtain mustn’t catch the door leaf, closer, shutter guides or other moving components. Its mounting position also needs to preserve the usable passage and allow cleaning, inspection and replacement without dismantling unrelated equipment.
Will a strip curtain stop dust and insects completely?
No. Overlapping strips can reduce their movement through an opening, but gaps appear during passage and air can move around the curtain. Treat it as one part of dust or pest control. Cleaning, suitable extraction and the condition of the surrounding building remain important.
Choose a curtain people can use comfortably
A suitable pedestrian curtain balances easy passage with useful separation. Strip dimensions matter, but so do material grade, overlap and accurate fitting.
Choose around the people using the opening every day. A curtain that closes reliably and remains manageable is more useful than a heavier specification that staff leave tied back.
For help specifying a made-to-measure curtain for your premises, Contact Us.