How to Choose PVC Strip Thickness for Forklift Routes
For forklift routes through an industrial door up to 5m high, 300mm x 3mm PVC is a practical starting point. Choose the strip size alongside opening height, traffic, temperature and draught exposure, because heavier strips need more force to push aside.
A busy loading bay is a different PVC strip curtain application from a pedestrian doorway or freezer entrance. The aim is reliable closure after each crossing, without creating unnecessary resistance or restricting visibility. Start with the standard sizes, then assess the conditions around your opening.
Key Takeaways
- Use 300mm x 3mm as a starting point for industrial forklift openings up to 5m high.
- Consider the 400mm-wide, 4mm option for taller industrial openings, with suspension designed for the additional weight.
- Choose temperature grade separately from thickness, and balance overlap against passage resistance.
- Ribbed PVC helps with repeated contact, but visibility, fitting and maintenance still matter.
Compare Standard PVC Strip Thickness and Width
Common PVC strips range between 2mm and 4mm thick. The usual width-and-thickness combinations are 200mm x 2mm, 300mm x 2mm, 300mm x 3mm and 400mm x 4mm.
The figures below distinguish application guidance from product-specific height limits.
| Strip width x thickness | Typical application guidance | Approximate mass per 50m roll | Listed product maximum height |
|---|---|---|---|
| 200mm x 2mm | Pedestrian curtains under 3m | 25kg | 2,500mm |
| 300mm x 2mm | Pedestrian and light-industrial curtains | Not stated | Not stated |
| 300mm x 3mm | Heavy-duty industrial curtains up to 5m | 55kg | 5,000mm |
| 400mm x 4mm | Very heavy-duty industrial curtains over 5m | 100kg | 10,000mm |
The application guidance comes from the Discount PVC Curtains guide. The roll masses and listed maximum heights come from the Red PVC 50m roll specification.
These figures use different scopes. For example, the general guide places 200mm x 2mm below 3m, while the listed product maximum is 2.5m. A general size recommendation isn’t a universal installation limit.
A roll’s listed mass isn’t the finished curtain’s installed load, which depends on strip length, quantity, overlap and suspension hardware. When ordering a PVC roll, check the supplied roll width as well as its length, since roll data is product-specific.

Match the Size to Forklift Traffic
Height narrows the choice, but traffic determines how the curtain behaves throughout the working day.
Use 3mm as an industrial starting point
For an industrial opening up to 5m high, 300mm x 3mm is a useful heavy-duty starting specification. It offers more substantial material than pedestrian-grade 2mm strips without the weight of the 400mm-wide, 4mm format.
However, forklift frequency alone doesn’t justify choosing the heaviest option. Repeated passage also demands manageable resistance and strips that settle back properly.
Include the load profile in the decision. Protruding pallet wrap, sharp packaging and uneven stacks can snag PVC regardless of thickness. Clearance must accommodate the largest load, not just the truck.
Keep pedestrian access manageable
Thicker PVC is heavier, while wider strips are harder for pedestrians to push aside. Fitting the largest format throughout a mixed-use doorway can make everyday walking access unnecessarily difficult.
A pedestrian door under 3m generally suits a 200mm-wide PVC strip, 2mm thick, under the guide’s application recommendations. The wider 300mm x 2mm option suits pedestrian and light-industrial curtains.
Where people and forklifts approach the same opening, clear PVC supports sightlines. However, transparency doesn’t replace pedestrian segregation, controlled crossings or suitable site traffic rules.

Choose Temperature Grade and Surface Separately
PVC strip thickness describes the material’s dimensions. It doesn’t establish its cold-temperature flexibility or surface resistance.
Standard and polar grades have different limits
Published operating limits for standard temperature PVC vary by product, so its temperature range isn’t universal. The Discount PVC Curtains guide gives -10°C to +40°C, while the Red PVC specification gives -15°C to +50°C. These are product-specific ranges, not one interchangeable standard.
Polar grade PVC is designed for a cold room, walk-in freezer or deep-freeze environment. The guide’s polar range is -40°C to +25°C, with flexibility retained down to -40°C.
Thickness doesn’t turn standard PVC into freezer-grade material. Cold flexibility depends on formulation, so choose a grade based on operating temperature. Our guide to PVC strips for freezer doorways covers the effect of cold conditions on passage and closure.
Ribbed strips suit repeated contact
Ribbed PVC has raised ribs on both sides. These absorb contact from forklifts and crates and help protect the main strip surface against abrasion, which can extend curtain life.
This makes ribbed material useful where pallets repeatedly brush through the opening. However, it doesn’t make the curtain immune to sharp edges or badly presented loads.
Compare clear and ribbed PVC curtains alongside the thickness decision. Smooth clear strips prioritise visibility, while ribbed surfaces suit harsher contact. Dirt and damage still need attention with either finish.
Balance Draught Control Against Easy Passage
A heavier curtain can offer better stability, but thickness alone won’t solve every airflow problem.
Consider exposure and overlap together
Taller strips have more exposed surface, while draughts and pressure differences can hold them away from their resting position. Wider, heavier PVC strips may suit these conditions better than lightweight pedestrian strips.
Overlap matters too. Greater coverage can limit air exchange and support temperature control, but it also increases the material traffic must move through. A 25% overlap is one possible arrangement, not a universal freezer specification.
Balance strip thickness, width, overlap, and exposure to reduce gaps without making passage difficult. Simply adding more PVC can create a curtain that’s hard to cross yet still hangs poorly.
Judge the curtain after normal traffic
Assess closure after a forklift passes through, rather than judging a stationary curtain. Strips should return across the opening without catching on neighbouring panels or remaining swept sideways.
A curtain that looks fully covered at rest can still leave persistent gaps after normal forklift traffic.
PVC strips reduce air exchange but aren’t airtight. An external loading opening still needs a suitable security and weather barrier. We install insulated roller shutters and high-speed doors where the wider access arrangement requires them.
Keep Specialist Grades Separate From Thickness
Colour, opacity and welding protection are separate specification choices. None replaces the need to select a suitable thickness.
Clear PVC usually supports visibility on forklift routes. Opaque PVC reduces through-vision, so it needs particular care wherever traffic approaches from both sides. Standard blackout PVC is black; custom colour matching is available in some ranges with a minimum order of 250kg. If the curtain receives direct sunlight, check whether the product is UV stable, since tint and thickness don’t establish UV resistance.
Where a route passes welding work, welding grade PVC is needed instead of ordinary clear or coloured material. It screens welding flash, harmful UV radiation, welding spatter and hot particles.
The ISO 25980:2023 welding-screen standard addresses protection against harmful optical radiation and spatter near arc welding. BS EN ISO 25980 replaced EN 1598.
HSE’s welding control guidance says welding screens should meet BS EN ISO 25980 or provide equivalent protection. Thickness or tint alone doesn’t establish that protection.
Fit and Maintain the Curtain for Its Weight
Even correctly selected PVC can perform poorly if the suspension is unsuitable or damaged strips remain in service.
Use proper suspension and finished lengths
A hook-on suspension system or bullet rail supports individual strips and allows them to be replaced. Fixing PVC directly to a wall can weaken the material around the fixings and make tearing more likely.
The rail and supporting structure must carry the installed curtain load and repeated pulling forces. Thin insulated doorway panels need an appropriate fixing arrangement, rather than reliance on their surface skin alone.
Measure the finished drop from the actual hanging position. Strips that drag can catch beneath wheels, while excessive bottom clearance leaves an unwanted gap. Our made-to-measure PVC curtain installation accounts for the opening and traffic requirements.
Clean without clouding the PVC
Use warm soapy water and a soft cloth. Keep strips hanging vertically while wiping, rather than bending or bunching them during cleaning.
Avoid solvents, harsh chemicals and abrasive cleaners because they can cloud or damage PVC. Reduced clarity matters on forklift routes, where drivers and pedestrians need useful sightlines.
During routine inspections, look for splits, missing strips, curling and damaged suspension plates. Replace individual worn strips before gaps become persistent. More thickness won’t compensate for a damaged curtain or loose mounting system.
Frequently Asked Questions
Do PVC strip curtains work on forklift routes?
Yes. Overlapping strips part around passing traffic, then return to reduce draughts, dust movement and temperature loss. Their effectiveness depends on overlap, condition and how often the opening is used.
They don’t create an airtight seal or replace an insulated external door. Strips left tied back provide little separation.
Which size suits an industrial door over 5m high?
The guide recommends 400mm x 4mm for large industrial curtains over 5m. The separate Red PVC product specification lists a maximum height of 10m for that size.
That product figure doesn’t establish a universal height limit across all grades and suspension systems. The installation needs a compatible rail, support structure and strip arrangement.
Does thicker PVC always last longer?
No fixed lifespan follows from thickness alone. More substantial material suits heavier-duty applications, but abrasion, sharp loads, cold flexibility and mounting condition also affect wear.
Ribbed surfaces can help with repeated contact. Regular cleaning and replacing damaged strips help preserve visibility and coverage.
Choose a Curtain That Closes Reliably
The right PVC strip thickness balances opening height, traffic resistance and operating conditions. For many forklift routes, 300mm x 3mm is a sensible starting point; taller openings may need 400mm-wide, 4mm strips.
Choose temperature grade and overlap alongside size. Reliable return after passage matters as much as how substantial the curtain looks when still.
For a made-to-measure curtain suited to your doorway and forklift traffic, Contact Us to arrange a free survey.
Discover more from UK Doors and Shutters
Subscribe to get the latest posts sent to your email.




Leave a Reply
Want to join the discussion?Feel free to contribute!