Can a Revolving Door Be the Only Accessible Entrance?
No. A revolving door cannot be the only accessible entrance under England’s Approved Document M guidance. Where one is installed, a separate accessible door should sit immediately beside it.
Revolving door accessibility depends on a usable alternative, not larger rotating compartments. Property owners should review the full entrance route, including how a disability may affect the approach or operation for people with disabilities.
Key Takeaways
- Provide an adjacent, signed accessible alternative to the revolving door.
- Measure effective clear width, rather than the nominal door leaf.
- Allow sufficient approach space and manageable opening effort.
- Plan accessible escape separately from everyday entry.
1. What the Entrance Guidance Requires
Paragraph 2.20 of Approved Document M, Volume 2 states that revolving doors aren’t considered accessible. It identifies difficulties and injury risks for people with assistance dogs, visual impairments or mobility difficulties, and parents with pushchairs.
The guidance calls for an immediately adjacent entrance door meeting the relevant manual or powered-door provisions, with accessible signage. This accessibility guidance applies to buildings other than dwellings in England; other UK nations have their own frameworks.

Revolving doors rotate around a central shaft, limiting direct air exchange. However, energy-saving benefits don’t remove access requirements. A slower setting doesn’t make one the accessible route.
In buildings with entrance structures that include one, the alternative should remain available during opening hours, without furniture, locked leaves or security shutters obstructing passage.
2. Door Width and Wheelchair Turning Space
Measure the usable opening
Effective clear width is the unobstructed passage through the open doorway. Frames, opening angles and projecting hardware can reduce it.
Entrance design should account for mobility needs and the manoeuvring requirements of a wheelchair user.
These commonly cited BS 8300 design references concern different doorway situations.
| Doorway situation | Recommended clear width |
|---|---|
| External entrance or internal entrance lobby door | 1,000 mm |
| Straight-on wheelchair approach | 800 mm |
| Right-angle approach from a 1,200 mm route | 825 mm |
The entrance recommendation must remain distinct from approach-based figures for other doorways. These aren’t universal statutory minima.
Historically, BS 8300:2009, published on 28 February 2009, addressed effective clear width in paragraph 6.4.1. Its Table 2 allowed existing-building openings significantly below 800 mm. Those allowances shouldn’t become a default specification for a new entrance.
Leave room beyond the doorway
A 1.5 m-diameter wheelchair turning circle is a traditional reference. Later inclusive-design guidance also uses 1.8 m spaces for greater manoeuvring room. Neither figure defines a suitable revolving-door diameter.
Allow space to approach, operate the alternative door and continue through. Prefer a level threshold; where unavoidable, BS 8300 guidance generally limits a raised threshold to 15 mm with suitable profiling.
Our guide to door opening force and accessibility covers another barrier: a wide door that’s too difficult to open.
3. Accessible Entry Doesn’t Guarantee Accessible Escape
Stair width and assisted evacuation
BS 9999:2008, published on 31 October 2008, belongs to the historical evacuation discussion. Paragraph 46.3 recognises that operating an evacuation chair safely and effectively can require as many as four people.
A 1.5 m clear staircase can accommodate a 700 mm allowance for a mobile person alongside an 800 mm allowance for a firefighter travelling against the flow. That calculation doesn’t establish sufficient space for every assisted evacuation manoeuvre.
Manually carrying an occupied wheelchair can require at least three people. An unoccupied powered wheelchair’s weight alone can make manual handling impractical. These figures aren’t handling instructions; assisted evacuation requires trained staff and a suitable fire-risk assessment.
Fire safety design for buildings should account for varied occupant needs. A person’s disability can affect route choice and the assistance they need. People with disabilities should help inform evacuation plans.
Evacuation lifts and personal plans
NIST’s 2005 World Trade Center findings included estimates of approximately 8% of occupants having disabilities, including 6% with mobility impairments. Survivors descended stairs at roughly half the slowest previously measured non-emergency evacuation speed.
NIST recommended fire-protected, structurally hardened lifts to support disabled occupants’ evacuation. Ordinary passenger lifts aren’t automatically suitable.
Personal Emergency Evacuation Plans are person-specific and location-specific, but fire evacuation plans must also cover the building’s egress routes. Overreliance on individual plans can leave visitors or people without assistants at risk; inclusion and safety require arrangements that account for these gaps.
The US Access Board’s evacuation guidance likewise stresses planning for all occupants, although it isn’t UK law. Article 11 of the 2006 UN Convention on the Rights of Persons with Disabilities requires protection in situations of risk, reinforcing the need for inclusive fire-safety policy.
Frequently Asked Questions
Can a large revolving door accommodate a wheelchair?
Some larger models can physically accommodate certain wheelchairs. However, compartment size alone doesn’t address timing, turning, assistance dogs or independent operation. Under England’s guidance, an adjacent accessible alternative remains necessary.
Would a round elevator improve entrance accessibility?
A round elevator has a circular shaft and cabin, without internal cabin corners. However, circular geometry doesn’t automatically mean a smaller installation footprint or wider doorway than a rectangular lift.

A central location may suit circulation or architectural preferences, but it isn’t inherently more accessible. Depending on the system, features can include automatic doors, button or sensor controls, voice activation, emergency stops and intercoms. Low-rise platform lifts are a separate category.
Neither lift shape nor controls resolve an inaccessible entrance. The route to the lift must work first.
Provide an Accessible Route Beside the Revolving Door
A revolving entrance needs a usable adjacent alternative, with suitable clear width, approach space and operation. Accessible escape also needs its own planned provision.
At UK Doors & Shutters, we install, repair and maintain automatic doors. Contact Us to discuss an entrance improvement or arrange a free survey.