Revolving Door Sizing for Peak Entrance Traffic
Revolving door sizing starts with your busiest arrival period, then matches that demand to the practical capacity of a specific door configuration. Diameter matters, but compartment space, wing count and access controls also affect how quickly people pass through.
A door’s practical capacity is more useful than its theoretical maximum because real users pause, carry bags and move at different speeds. Start with the traffic arriving at your entrance, rather than choosing a diameter from the available floor space alone.
Key Takeaways
- Base the specification on short peak intervals, with separate counts for incoming and outgoing pedestrians.
- Compare capacity figures using the same time period, direction of travel and operating assumptions.
- Allow room for an adjacent accessible entrance, clear circulation and maintenance access, alongside the revolving door itself.
Assess Peak Entrance Demand
A daily visitor total won’t reveal whether your entrance can handle a concentrated morning arrival. The important measurement is how many people reach it during the busiest short interval.

Count Arrivals at the Entrance
Record incoming and outgoing movements separately during representative busy periods. Five-minute counts reveal concentrated demand, while one-minute observations help identify shorter surges hidden within that average.
Include shift changes, lunchtime movements and event admission where these apply. Also note luggage, pushchairs and deliveries because the same pedestrian count can create different demands on compartment space.
Count people reaching the entrance, rather than only those passing through. Otherwise, an existing queue can make an undersized door appear to meet demand.
Use Occupancy-Based Estimates Cautiously
Where measured traffic isn’t available, occupancy can provide an initial planning estimate. FAAC Entrance Solutions UK describes a method using 15% of building users arriving over five minutes.
For 2,000 staff, that produces 300 arrivals in five minutes, or 60 people per minute. This is an occupancy-based estimate, not a universal standard or a measured arrival rate.
Peak demand and daily workload also answer different questions. Our guide to commercial door duty ratings explains why sustained use needs its own consideration.
Compare Capacity by Diameter and Wing Count
Larger diameter generally provides more space, but diameter alone doesn’t establish usable throughput. Compare the complete configuration, including its operating mode.
Match Compartments to Your Users
Three-wing designs provide larger individual compartments than four-wing designs of a similar diameter. Four-wing designs divide the circle into more, smaller compartments.
That difference matters when people carry suitcases, accompany children or move less confidently. However, a larger compartment doesn’t automatically produce a higher pedestrian rate.
Manual and powered operation also create different conditions. For example, manual throughput depends partly on users maintaining movement. Powered-door capacity depends on its controlled operating sequence and the interruptions that occur during use.
Compare Practical Flow on the Same Basis
dormakaba’s KTV figures show why theoretical and practical capacity need separate treatment. These are configuration-specific planning figures, not universal ratings for every revolving door.
The published one-way figures illustrate the difference:
| Internal diameter | Theoretical capacity per hour | Practical capacity per hour |
|---|---|---|
| 2,000 mm | 1,440 people | 480 people |
| 2,400 mm | 1,800 people | 600 people |
| 2,700 mm | 2,400 people | 800 people |
The takeaway is the gap between ideal movement and practical use, rather than a universal diameter-to-capacity rule.
A theoretical figure assuming continuously occupied compartments isn’t interchangeable with a practical one-way capacity.
Keep direction explicit throughout the comparison. A combined incoming-and-outgoing figure can overstate capacity when assessed against a predominantly incoming morning peak.
Match Working Capacity to Your Busiest Interval
Express demand and capacity in matching units before selecting the number of doors. People per minute can’t be compared directly with people per hour.
For several identical doors serving the same route, divide the allocated peak demand by one door’s practical capacity. Then round up to a whole door. However, this calculation assumes pedestrians can reach and use each unit without another obstruction controlling the flow.
Allow headroom for uneven arrivals, foreseeable growth and operational interruptions. There isn’t a single spare-capacity percentage that suits every building. A staffed office entrance and a public attraction have different arrival patterns.
Access control also changes the calculation. Credential presentation, rejected access attempts and visitor assistance can interrupt movement, even when the revolving mechanism has spare capacity.
Assess the route beyond the door too. A reception queue immediately inside can prevent people leaving compartments promptly. Increasing the diameter won’t resolve a registration desk that blocks the discharge area.
Where the available footprint can’t support the required revolving-door arrangement, another entrance type may fit better. Our comparison of revolving and sliding door systems explains their different access characteristics.
Plan the Accessible Entrance and Operating Layout
Treat the whole entrance as one circulation arrangement. Revolving-door capacity is only part of that design.
Provide an Immediately Adjacent Accessible Route
In England, paragraph 2.20 of Approved Document M, Volume 2 states that revolving doors aren’t considered accessible. Where one is provided, the guidance calls for an immediately adjacent entrance door meeting the relevant provisions, with accessible signage.
A larger diameter or slower rotation doesn’t replace that alternative. The adjacent route must remain usable during opening hours, without locked doors, deliveries or furniture obstructing passage.
Its users also need enough room to approach, operate the door where necessary and move into the building. Other UK nations have their own regulatory frameworks.

Protect Approach and Discharge Space
People need room to select a compartment before entering and move away afterwards. Queues should leave the accessible route and escape routes clear.
Keep promotional stands, bins and reception furniture away from approaches and detection areas. These objects can narrow circulation or interfere with normal operation.
Also account for crossing traffic. People leaving lifts, approaching reception or waiting for colleagues shouldn’t collect directly beside the revolving-door exit.
Measure the Complete Installation Footprint
An internal drum diameter isn’t the structural opening size. The surrounding enclosure, framing and supporting construction require additional space.
The installation layout needs to distinguish internal diameter, external dimensions, passage openings and usable height. Canopy dimensions and access to drive equipment also affect how the assembly fits beneath the building structure.
Floor construction deserves equal attention. The base, finished floor levels and entrance matting must work together without introducing obstructions or awkward changes in level. Where the enclosure meets external paving, the design also needs suitable weather protection and drainage.
Measure the surrounding circulation area as part of the footprint. A drum may fit between two columns while leaving insufficient room for people to approach comfortably.
Our commercial door installation guide covers wider site-planning considerations. A complete specification should establish both the space the equipment occupies and the space pedestrians need around it.
Account for Safety Standards and Ongoing Door Use
A high-capacity entrance still needs predictable movement and reliable protective systems. Capacity targets must work within the door’s safe operating arrangements.
Keep Safety Settings Within the Design
BSI lists BS EN 16005:2023+A1:2024, published on 30 November 2024, for powered pedestrian doorset safety requirements and testing.
Don’t treat faster rotation as an ordinary response to queues. Changes to speed, force or detection settings can affect the complete safety system and belong with a competent door engineer.
Emergency escape needs separate assessment too. Everyday entrance throughput doesn’t establish a door’s suitability within the building’s fire strategy. Where changes affect escape arrangements, involve a competent fire-safety professional.
Preserve Capacity Through Maintenance
Servicing helps retain the performance the entrance was designed to provide. Repeated hesitation, scraping or unexplained stopping can disrupt traffic and need assessment.
Maintenance should follow the manufacturer’s instructions, the amount of use and the door’s condition. Relevant inspection points include moving components, sensors, control equipment and structural fixings.
We provide automatic door installation and servicing for commercial premises. Between visits, staff should keep approaches clear and record unusual behaviour. If movement becomes unpredictable, keep people clear and direct them to another suitable entrance.
Frequently Asked Questions
What Diameter Revolving Door Do I Need?
There isn’t one diameter that suits a particular building occupancy. Start with peak pedestrian demand, then compare configuration-specific practical capacities.
The dormakaba figures above illustrate why a nominal diameter isn’t enough. Compartment layout, direction of travel and operating assumptions remain part of the selection.
Should the Accessible Door Count Towards Peak Capacity?
Assess the accessible door’s expected traffic separately, then include it in the overall entrance plan. Its availability and circulation space must remain protected.
Don’t assume it can absorb every revolving-door queue. That could create congestion on the route needed by people who can’t comfortably use the revolving entrance.
Specify for the Queue You Need to Prevent
Reliable revolving door sizing matches measured peak demand with practical throughput, while protecting accessible circulation. Diameter is one part of that decision.
A workable specification also accounts for the surrounding layout and safe operation throughout the door’s service life.
For help planning an automatic entrance around your building’s traffic and access needs, Contact Us.