Revolving Door Sensors: How Obstruction Detection Works
Revolving door sensors detect people and objects, then tell the controller to slow, stop or change the door’s movement. In an automatic revolving door, the response depends on where detection happens, which device activates and the door’s operating mode.
For building managers, a door that stops unexpectedly can indicate a working safeguard or a fault. Understanding that difference starts with the separate jobs of activation sensors, presence detectors and safety rails.
Key takeaways
- Activation sensors start movement, while safety devices protect people near moving wings and trapping points.
- Some detectors slow rotation before a closer detection zone triggers a complete stop.
- Sensor functions, restart timing and coverage depend on the door model, safety package and operating mode.
What revolving door sensors detect
A revolving entrance has several hazard areas. These include approaching wings, the central column and the points where moving panels pass fixed edges.
Activation detects approaching users
A door activation sensor tells the controller that someone wants to enter. Radar commonly performs this role because it detects movement towards the entrance.
However, a door activation request doesn’t prove that a compartment is clear. A stationary person needs protection too, so activation alone cannot provide the complete safety function.
Safety detection protects occupied areas
Safety sensors monitor protected areas around the moving door set. Depending on their position and configuration, they can request reduced speed or stop rotation.
Contact-sensitive rails provide another layer of protection. ADSA’s automatic door safety FAQs identify BS EN 16005 as the standard covering safety in use and test methods for automatic pedestrian doors.

Illustrative sensor layout. Actual positions and coverage vary by door configuration.
Infrared, radar and photocells compared
Sensor technology describes how detection works. It doesn’t, by itself, determine whether the controller slows or stops the door.
These are the main distinctions when comparing technologies.
| Technology | What it detects | Main limitation |
|---|---|---|
| Active infrared | Reflected infrared light within a detection field, detected by an infrared safety device | The detection field may not cover the entire protected area |
| Radar | Movement within its detection field | A motion-only unit cannot detect a stationary occupant |
| Photocell | An interruption across a defined light beam | A single beam doesn’t cover an entire compartment |
| Pressure-sensitive rail | Physical contact with a flexible edge | Contact occurs before the rail sends its signal |
Devices that look similar may perform different jobs, so selection must account for the protected area and controller compatibility. A non-contact door switch may provide an activation input, but it doesn’t replace presence protection. An infrared safety device’s actual coverage depends on mounting, adjustment and surroundings.
For example, the Hotron HR50 is a radar sensor for swing and sliding doors, with mounting heights up to 2.2 metres. The HR100/BL is a sliding-door activation system incorporating a pedestrian safety sensor, suitable for mounting up to 3 metres.
Those specifications don’t establish either product as a replacement revolving-door safety sensor. Door type and approved integration matter as much as mounting height.
Active and passive safety rails
Rubber safety profiles can look alike while operating differently. The distinction matters when interpreting a stop or specifying replacement parts.
Active rails send a contact signal
In active safety rails, a sensor in the safety profile sends a signal that stops the door set when someone presses the rail.
In the Boon Edam arrangements described here, active safety rails restart about one second after the rail is released. This release-and-restart sequence differs from other sensor responses.
A damaged or compressed rail can hold the door stationary even when the entrance appears clear.
Passive rails cushion an obstruction
A passive safety profile contains no sensor. With passive safety rails, the drive detects blocked movement and stops rather than receiving a contact signal from the rail.
The flexible profile reduces the impact of contact. Because it relies on the machine’s obstruction detection, its operation differs from an electrically monitored active rail.
The safety package, door dimensions and drive mechanism determine which profiles apply and whether they are active or passive.
How TRS and EBS control slow and stop zones
The following names describe Boon Edam safety arrangements. Other manufacturers may use different terminology, so these functions shouldn’t be assumed across every revolving entrance.
TRS Basic and the extension have different roles
The Top Rail Sensor (TRS) Basic slows the rotating door set when used alone. It doesn’t provide the additional stopping function simply because it detects an obstruction.
When a TRS extension is fitted, the extension triggers slowing and the TRS Basic triggers stopping. This arrangement allows an earlier speed reduction before the nearer protective function intervenes.
EBS responds according to the detection area
End Buffer Safety (EBS) slows the door set when it detects someone or something in its slow area. Detection within the stop area stops the door completely.
The sizes of both areas depend on the machine’s dimensions. They aren’t universal distances that an installer can copy between different entrances.
Floor conditions also affect protection. The ADSA bulletin on uneven floors discusses entrapment risks beneath revolving-door wings, so floor alterations need consideration alongside sensor coverage.

Illustrative slow and stop areas, not installation dimensions.
Model-specific protection around the door set
A model name alone doesn’t describe every installed safeguard. Dimensions, optional safety packages and operating modes change which devices apply.
Tourniket and Tournex arrangements
Tourniket and Tournex installations can use combinations of top-rail detection, end-buffer protection and safety profiles, according to their configuration.
On a Tournex, the Centercolumn Ceiling Sensor (CCS) is a ceiling sensor that stops the wings when it detects a person or object near the central column. It protects a different area from an entrance-mounted detector.
Maintenance therefore needs to cover the complete sensor layout. Testing only the approach detector leaves the CCS ceiling sensor and other protective functions unassessed.
Duotour sliding and folding modes
On relevant Duotour configurations, the Horizontal Boon Sensor (HBS) reduces speed during rotation. In sliding-door mode, it reopens the sliding doors.
The SWS operates only in sliding-door mode and gives an audio alarm when it detects a person or object. Its stated response is an alarm, so it shouldn’t be described as a universal stopping device.
During wing folding, the Safety Curtain Door Wing (SCD) is the only active safety sensor for that folding movement.
Ceiling sensors provide another function: if someone becomes locked inside a closed segment, they trigger one additional segment of rotation. The number of ceiling sensors depends on the machine diameter.
These mode-dependent responses explain why a sensor can appear inactive during one movement yet operate correctly during another.
Choosing and commissioning a safe sensor system
Replacing a detector involves more than matching its housing. The system must protect the intended area and communicate correctly with the door controller.
Match protection to the entrance
Selection should account for wing geometry, mounting position, controller inputs and every operating mode. The assessment also needs to consider slower users, luggage and pushchairs.
The EDSF guidance on EN 16005 provides context for protective measures on powered pedestrian doors. A sensor purchase alone doesn’t establish the safety of the complete installation.
In the UK, BSI states that BS 7036:2026 risk-assessment guidance should be read alongside BS EN 16005:2023+A1:2024 for powered pedestrian doorsets.
Test the complete sequence before handover
Commissioning should follow mechanical installation and alignment. A competent engineer then configures detection fields and tests the required slowing, stopping and restart responses.
Testing also needs to cover sliding or folding modes where fitted. Records should identify the devices, settings, results and maintenance requirements.
Our BS EN 16005 safety guide explains how inspection and servicing fit into ongoing automatic-door safety.
Recognising a sensor fault safely
Repeated unexplained stops, delayed responses and inconsistent slowing deserve attention. However, these symptoms don’t prove that the sensor itself has failed.
Dirt, displaced fittings or objects inside a detection field can create obstruction signals. Mechanical resistance, damaged profiles and wiring faults can also affect operation.
A stopping door may be responding correctly to a hazard. Increasing force or disabling detection can remove that protection without resolving the cause.
Staff can record when the fault occurs, the operating mode and any displayed error. They shouldn’t use their body to test a moving wing or reach into trapping points.
If protection appears unreliable, take the entrance out of service and direct users through a safe alternative route. Our guide to revolving doors stopping between rotations explains other causes of interrupted movement.
Maintaining sensors between faults
Regular servicing helps identify sensor drift, damaged rails and worn mechanical components before they cause disruption. It also provides an opportunity to test functions that staff rarely see operating.
Professional service intervals should reflect the manufacturer’s maintenance schedule, traffic levels and operating environment. A heavily used public entrance needs closer attention than a lightly used installation.
Between visits, keep detection areas clear and follow the documented cleaning instructions. Avoid moving sensor brackets or adjusting sensitivity to cure nuisance stops.
After impact damage, floor works or changes around the entrance, arrange an assessment of the affected protection. A new mat, display or altered floor level can change the conditions under which the system operates.
Keep maintenance reports together with fault records. This helps an engineer distinguish a recurring detection issue from a new mechanical problem.
Frequently asked questions
Does every detection stop the door immediately?
No. The programmed response may be slowing, stopping, reopening sliding panels or sounding an alarm. For example, EBS distinguishes between slow and stop areas, while SWS provides an audio warning in sliding-door mode.
Does the door always restart after one second?
No. The approximately one-second delay described above applies after an active safety rail is released on the relevant Boon Edam arrangement. Other detections, faults and operating modes follow their own control sequences.
Keep the whole protection system working
Revolving door sensors work together with safety profiles, drive controls and correctly configured operating modes. Complete-system testing matters because a working approach detector doesn’t prove that every trapping point is protected.
At UK Doors & Shutters, we provide automatic-door servicing and repair support. If your entrance stops unpredictably or its safety response has changed, Contact Us to arrange professional attention.




Leave a Reply
Want to join the discussion?Feel free to contribute!